X10 PRO Wired-in Coupler Repeater Amplifier (XPCR)

Free shipping on orders over $29.99

$68.62

$ 27 .35 $27.35

In Stock

About this item

  • Amplifies X10 signals to improve system reliability
  • Repeats X10 signals from one phase to another
  • Perfect for split-phase and 3-phase systems
  • Covers homes measuring over 3,000 sq. feet


You can improve X10 performance and conveniently control X10 modules placed on different phases of your home's electrical system by installing the X10 PRO Wired-In Coupler Repeater Amplifier. The coupler/repeater serves as a signal-bridge across split-phase and 3-phase electrical systems, repeating X10 signals from one phase to another. Devices such as TVs, computer equipment, or anything with a complex power supply can absorb X10 signals. Even if you have a smaller home, but you use a great number of electronic devices, then installing the X10 coupler repeater is a great way to ensure maximum functionality of your X10 system. The X10 coupler repeater can work on three-phase (120/208 VAC) electrical systems, commonly found in commercial apartments and condominiums. In split-phase installations, often found in single family homes, one of the wires will be capped off and unused. The X10 coupler repeater has the same powerful capabilities as the standard X10 signal bridge, but it also boosts the X10 signal and blasts it out both legs of electricity at the same time. As long as the initial incoming signal is 100mV, the coupler repeater will kick up the outgoing signal to over 5 volts (depending on your home's impedance). Covers homes measuring over 3,000 sq. feet. NOTES: 1. The XPCR is not a filter. 2. Installation should be performed by qualified installers only. The main breaker must be turn-off during installation. The coupler must be installed in a suitable workbox or enclosure per local code.


Bob Bullard
July 15, 2025
Have had an X10 system for many many years but have over time been disappointed that some lights did not always act/react to their codes. I had been tempted to get this unit for some time and finally broke down and am I ever glad I did. Lights that had been finicky now respond each and every time. Why oh why did I ever delay getting this item to bridge the two phases at my breaker panel and have the codes repeated so there was no loss in the command or degradation of the signal.
Jacqueline Tremblay
July 4, 2025
Produits fonctionne très bien
Karl Grollmuss
May 9, 2025
okay
Gizmo
March 30, 2025
Cleared up my intermittent X10 transmissions after installation.
Jean LeFrancois
March 2, 2025
Did not fix the problem I was suppose to fix the technology is obsolete base on what I red with the new del light bull who create a lost of noise.
Réal Cyr
January 21, 2025
Fonctionne très bien, fait ce que ça doit faire .... améliore grandement les produits X-10 en corrigeant l'accès au phase du panneau électrique
Customer
December 26, 2024
Hi everyone: I have had X10 installed for many many years. I have had periods when certain lights would be frustrating intermittent. I always presumed it was the module(s), I bought more with limited success. The more I studied comments, I realized I had one circuit in particular which was always a problem. So I relocated the computer module from the computer room out and plugged it in a plug in the problem circuit (it need not be plugged to computer unless changes are required) – this has so far corrected my problem. I have two controllers, so if problem returns, I may run two controllers. Hope this helps someone out there.